TM 9-2815-202=34
8-20. ENGINE RUN-IN (Cent)
Table 8-3. Short Run-In Schedule
Period
Time
Engine Speed
Load
Number
(Minutes)
(RPM)
(Brake Horsepower)
1
5
600
0
2 !5 1200
0
3
30
2500
0
4
15 2300 107
5 15 2300 230
6 15 2300 Full Power Check
7 5 600 0
(Cooling Off)
Table 8-3.1. Run4n Schedule (Model 7083-7391 Only)
Period
Time
Engine
Speed
Load
Number
(Minutes)
(RPM)
(Brake Horsepower)
1
10 1200 56
2 5 2475 0
3
10 2300 396
4
5
2475
0
5 20 2300 Full Power Check
6 5 2475
0
(Cooling Off)
(2) Tighten cylinder head bolts and adjust exhaust valve clearance after run-in (Refer to Para 4-27
and 8-4 respectively).
(3) For model 7083-7391 only, retorque right bank exhaust manifold stud nuts to 43-48 Ib-ft (59-67
N-m) after run-in (Refer to Para 5.1-3).
8-50
Change 1