TM-9-2815-220-24

AVDS-1790 2CA, 2DA and 2DR Air-Cooled 12-Cylinder Diesel Engines

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL FOR AVDS-1790 2CA, 2DA and 2DR Air-Cooled 12-Cylinder Diesel Engines

  TM-9-2815-220-24 - Page 474 of 1563

TM 9-2815-220-24
WIRING HARNESS REPLACEMENT, STARTER, SMOKE GENERATOR, AND DUST
DETECTOR WITH LOW VOLTAGE PROTECTION MODULE TOP MOUNTED
(2CA, 2DA) (PART NUMBERS 11655454, 12314619, AND 12354468)
0060 00
INSTALLATION (Continued)
NOTE
For smoke generation systems with single-solenoid configuration,
harness installation instructions are covered in step 4.
For smoke generation systems with dual-solenoid configuration,
harness installation instructions are covered in step 3.
4. Harness installation with single solenoid smoke generator harness.
a. Install connector (42) at smoke generator solenoid (43).
b. Install ground lead (46) with screw (44) and new lock washer (45) (item 93, WP 0175).
c. Install loop clamps (49) with assembled washer screws (48).
d. Install tie wraps (47) (item 81, WP 0175) as needed.
42
43
46
44, 45
47
48, 49
WP 0060 00-20


Back to Top