2-39. WATER CROSSOVER REPAIR (Cont’d)
CAUTION
Thermostat must be installed correctly or engine damage may
result.
For general assembly instructions, refer to para. 2-12.
1. Install thermostat (9), gasket (8), and water outlet (7) on water crossover (11) with two washers (4),
capscrew (6), and stud (5). Tighten capscrew (6) and stud (5) t
O 25 lb-ft (34 N•m).
2. Coat threads on heater hose nipple (12), bypass hose nipple (10), and de-airation nipple (2) with
pipe sealing compound and install in water crossover (11).
3. Coat threads on glow plug controller (1) and temperature switch (3) with pipe sealing compound
and install in water crossover (11).