TM 9-2920-225-34
FRAME 2
I
1.
2.
3.
4.
Check that stator (1) and stator terminal (2) are not cracked and that there
are no stripped threads or loose pins. If stator or terminal is damaged,
generator is nonrepairable.
Check that stator (1) has no broken windings or loose connections. Resolder
any loose or broken connections.
Check that stator (1) has no grounds between three pins (3, 4 and 5) on
terminal (2) and outer case of stator. Touch one test probe of multimeter
to outer case and other test probe to each pin. If ground is present,
generator is nonrepairable.
CAUTION
Do not use a battery or test lamp
test.
Reverse battery connection
instantly .
to make a continuity
will burn out diodes
Check that stator (1) has continuity between three pins (3, 4 and 5) on
terminal (2). Touch test probes of multimeter to pins ( 3 and 4), pins
(3 and 5) and pins (4 and 5). If continuity is not made between three pins,
generator is nonrepairable.
GO TO FRAME 3