TM-9-2920-225-34

GENERATOR ASSEMBLY; PRESTOLITE AMA-5102UT; LEECE-NEVILLE 3002AC, 3002AD, 3002AE, 5504AA, 5504AB, 2184AC, 5300GP

TECHNICAL MANUAL; MAINTENANCE; DIRECT AND GENERAL SUPPORT LEVEL

FEBRUARY 1981

  TM-9-2920-225-34 - Page 28 of 262

TM 9-2920-225-34
FRAME 3
I
1
0
2.
3.
Check
rectifier (1) using multimeter as follows.
NOTE
On ohmmeters that use one 1 1/2-volt dry cell, low
resistance readings will be approximately 20 to 30 ohms.
On ohmmeters that use a 3-volt dry cell, low resistance
readings will be approximately 10 to 15 ohms.
Touch negative test probe of multimeter to output terminal (2). Multimeter
must show low resistance when positive test probe is touched to rectifier
terminals (3, 4, 5, and 6). Get a new rectifier (1) if it does not show
correct reading.
Touch positive test probe of multimeter to output terminal (2). Multimeter
must show infinite resistance when negative test probe is touched to rectifier
terminals (3, 4, 5, and 6). Get a new rectifier (1) if it does not show correct
reading.
GO TO FRAME 4
TA103510
2-12


Back to Top