TM-9-2920-225-34

GENERATOR ASSEMBLY; PRESTOLITE AMA-5102UT; LEECE-NEVILLE 3002AC, 3002AD, 3002AE, 5504AA, 5504AB, 2184AC, 5300GP

TECHNICAL MANUAL; MAINTENANCE; DIRECT AND GENERAL SUPPORT LEVEL

FEBRUARY 1981

  TM-9-2920-225-34 - Page 29 of 262

TM 9-2920-225-34
FRAME 4
1.
2.
3.
Check rectifier (1) using multimeter as follows.
NOTE
On ohmmeters that use one 1 1/2-volt dry cell, low resist-
ance readings will be approximately 20 to 30 ohms. On
ohmmeters that use a 3–volt dry cell, low resistance
readings will be approximately 10 to 15 ohms.
Touch positive test probe of multimeter to screw hole
(2).
Multimeter must
show low resistance when negative test probe is touched to rectifier
terminals (3, 4, and 5).
Get a new rectifier (1) if it does not show correct
reading.
Touch negative test probe of multimeter to screw hole (2). Multimeter must
show infinite resistance when positive test probe is touched to rectifier
terminals (3, 4, and 5).
Get a new rectifier (1) if it does not show correct
reading.
END OF TASK
TA10351 1
2-13


Back to Top