TM 9-3990-260-14&P
(17)
Rotate cams (11) in left and right bracing mechanisms until shoring slots (12) on both sides
of ISO container are engaged.
(18)
If a cam (11) will not engage shoring slot (12), insert pin (17) into adjustment collar (15) and
turn, adjusting cam ( 11) forward or aft until cam (11) will engage shoring slot (12).
NOTE
Depending upon CROP distance from shoring slots, cams will engage in one of two posi-
tions depicted above as Nominal Position and Minimum Position.
If required, use a fork-
lift to position CROP so either the Nominal or Minimum position can be achieved.
2-37