LO-5-5420-202-13

M48A5 TANK CHASSIS AND M60A1 TANK CHASSIS

LUBRICATION ORDER

JANUARY 2011

  LO-5-5420-202-13 - Page 8 of 28

LO 5-5420-202-13
Card 8 of 22
NOTES:
4. SMOKE GRENADE LAUNCHERS.
a)
Before Firing: Wipe all surfaces dry.
b)
After Firing: Immediately clean with CLP (MIL-PRF-63460) and wipe dry. Apply a
light coat of CLP to all surfaces. Make sure all surfaces are coated. Do not wipe
dry. After firing, repeat process for 2 days.
c)
Inactivity: If not to be fired for an extended period, quarterly, clean with CLP, wipe
dry and apply CLP (MIL-PRF-63460) to all surfaces.
d)
Do not lubricate contacts at bottom of tubes.
WARNING
FRH fluid may cause irritation to the eyes and skin. Avoid contact with
eyes, skin, and clothing. Wear protective goggles, gloves, and
clothing.
If FRH fluid comes in contact with eyes or skin, flush the
area with water. Failure to comply may result in injury or illness to
personnel.
Cleaning Compound (MIL-PRF-680) is flammable and may cause
irritation to the eyes or skin. Use in well ventilated areas and keep
away from heat and open flames. Wear protective goggles, gloves,
and clothing. If compound comes in contact with eyes, flush
immediately with water. If compound comes in contact with skin, wash
with soap and water. Failure to comply may result in injury, illness or
death to personnel.
5.
HYDRAULIC BREATHER FILTER. Remove cap. Clean filter with cleaning compound
(MIL-PRF-680) and dry by shaking. Oil the filter using FRH fluid (MIL-PRF-46170). Do
not use OE/HDO oil. In extremely dusty conditions, service more frequently. Every month,
remove breather tube, clean with cleaning compound, and dip in FRH fluid. Do not use
OE/HDO oil.