TB 9-2320-279-13-1
0028-5/(0028-6 blank)
AC CONDENSER REPLACEMENT - Continued
DRAFT
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
Ensure preformed packings are in place in hoses prior to installation.
3. Install preformed packing (7) and hose (6) on fitting (8).
Torque hose (6) to 11-13 ft-lbs. (15-18 N•m).
4. Install preformed packing (4) and hose (3) on fitting (5).
Torque hose (3) to 15-18 ft-lbs. (20-24 N•m).
5. Connect connector (1) to connector (2).
FOLLOW-ON MAINTENANCE
1. Connect batteries (TM 9-2320-279-20).
2. Charge AC system (WP 0050).
3. Perform leak test inspection (WP 0049).
END OF WORK PACKAGE
HEMAC055