TB 9-2320-302-13&P-3
COMPRESSOR REPLACEMENT - CONTINUED
0016 00
0016 00-7
INSTALLATION - CONTINUED
WARNING
•
Contact with refrigerant can cause frostbite. Keep hands and face away to prevent personal injury.
•
Protective face shield must always be worn when refrigerant lines are opened, even if the gauges indi-
cate the system is empty.
•
Always use caution if a fitting is removed. Slowly loosen the fitting. If the system is still under any
pressure, release it slowly in a well-ventilated area.
•
DO NOT smoke when servicing A/C or wherever refrigerant gas may be present.
•
Failure to follow these warnings may result in injury or death to personnel.
NOTE
Install wires and hoses as tagged during removal.
10.
Apply refrigerant oil to new O-ring, remove cap, and install A/C hose (9) on compressor (1).
11.
Apply refrigerant oil to new O-ring, remove cap, and install A/C hose (8) on compressor (1).
449-057
1
8
9