TB-9-2320-302-13-P-3

CREW PROTECTION KIT; AIR CONDITIONING KIT PART 3 OF 3

TECHNICAL BULLETIN; OPERATOR’S, UNIT, AND DIRECT SUPPORT, MAINTENANCE MANUAL, INSTALLATION INSTRUCTIONS, AND REPAIR PARTS AND SPECIAL TOOLS LIST

MARCH 2008

  TB-9-2320-302-13-P-3 - Page 123 of 240

TB 9-2320-302-13&P-3
EVAPORATOR ASSEMBLY MAINTENANCE - CONTINUED
0017 00
0017 00-15
INSTALLATION
NOTE
The Air Conditioning Kit can be installed on vehicles with TB 9-2320-302-13&P-1 or TB 9-2320-302-
13&P-2 Crew Protection Kits. Perform steps 1 through 3 for TB 9-2320-302-13&P-2 Crew Protection Kit.
1.
Install rear evaporator mounting bracket (27), four washers (43), new lockwashers (42), and nuts (41) on roof frame
(44).
2.
Install front evaporator bracket (33), two washers (32), and new locknuts (31) on roof frame (44).
3.
Install front evaporator mounting bracket (28), two washers (35), and new locknuts (34) on front evaporator bracket
(33).
NOTE
The Air Conditioning Kit can be installed on vehicles with TB 9-2320-302-13&P-1 or TB 9-2320-302-
13&P-2 Crew Protection Kits. Perform steps 4 and 5 for TB 9-2320-302-13&P-1 Crew Protection Kit.
4.
Install rear evaporator mounting bracket (27), four washers (40), and bolts (39) on roof assembly (44).
5.
Install two thick washers (38), front evaporator mounting bracket (28), two washers (37), and bolts (36) on roof assem-
bly (44).
449-071
27
41,42,43
41,42,43
31,32
28
33
31,32
44
27
34,35
39,40
39,40
36,37,38


Back to Top