TB 9-2320-302-13&P-3
0018 00-1
CONDENSER REPLACEMENT
0018 00
THIS WORK PACKAGE COVERS
Removal, Cleaning and Inspection, Installation
INITIAL SETUP
Maintenance Level
Direct Support
Tools and Special Tools
Tool Kit, General Mechanic’s (Item 9, WP 0024 00)
Shop Equipment, Common No. 1 (Item 6, WP 0024
00)
Reclaimer, Refrigerant (Item 5, WP 0024 00)
Tool Kit, Refrigeration Equipment (Item 10, WP
0024 00)
Wrench Set, Torx (Item 11, WP 0024 00)
Materials/Parts
Oil, Lubricating, Refrigerant Compressor (Item 8,
WP 0025 00)
Rag, Wiping (Item 9, WP 0025 00)
Materials/Parts - Continued
Tag, Marker (Item 13, WP 0025 00)
Locknut (4)
O-ring (2)
Personnel Required
Two
References
WP 0014 00
Equipment Conditions
Vehicle parked on level ground (TM 9-2320-363-
10)
Parking/Emergency Brake applied (TM 9-2320-
363-10)
Engine OFF (TM 9-2320-363-10)
Ignition Key Switch in OFF position (TM 9-2320-
363-10)
A/C Refrigerant recovered (WP 0015 00)
WARNING
Contact with refrigerant can cause frostbite. Keep hands and face away to prevent personal injury.
Protective face shield must always be worn when refrigerant lines are opened, even if the gauges indi-
cate the system is empty.
Always use caution if a fitting is removed. Slowly loosen the fitting. If the system is still under any
pressure, release it slowly in a well-ventilated area.
DO NOT smoke when servicing A/C or wherever refrigerant gas may be present.
Failure to follow these warnings may result in injury or death to personnel.
CAUTION
Cap all A/C hose ends and component connections during removal to protect against contamination. Failure
to comply may cause damage to equipment.