TB 9-2320-302-13&P-3
A/C HOSE REPLACEMENT - CONTINUED
0020 00
0020 00-2
REMOVAL - CONTINUED
WARNING
•
Contact with refrigerant can cause frostbite. Keep hands and face away to prevent personal injury.
•
Protective face shield must always be worn when refrigerant lines are opened, even if the gauges indi-
cate the system is empty.
•
Always use caution if a fitting is removed. Slowly loosen the fitting. If the system is still under any
pressure, release it slowly in a well-ventilated area.
•
DO NOT smoke when servicing A/C or wherever refrigerant gas may be present.
•
Failure to follow these warnings may result in injury or death to personnel.
CAUTION
Cap all A/C hose ends and component connections during installation to protect against contamination. Fail-
ure to comply may cause damage to equipment.
NOTE
•
Tag wires and hoses to aid in installation.
•
Note routing of wires and hoses prior to removal to aid installation.
1.
Remove A/C hose (2) connection from condenser (1). Discard O-rings.
2.
Remove A/C hose (3) connection from condenser (1). Discard O-rings.
3.
Remove tiedown straps (4) and spiral wrap (5) as necessary from A/C hoses (2 and 3). Discard tiedown straps.
449-056
1
2
3
4,5