5-9.1. To avoid contamination of the treated surface,
apply primer according to procedures in Appendix A
(Navy) or TM 55-1500-345-23 (Army) within 72 hours
after conversion coating or perform temporary
preservation procedures (see paragraph 5-10) as soon
as possible.
5-9.2. If the surface becomes dirty or accumulates oil,
grease, fingerprints, or other contaminants, wipe prior
to painting with clean cheesecloth (CCC-C-440) and an
approved solvent.
5-9.3. If the surface is scratched or the conversion
coating is damaged, clean (refer to paragraph 5-2) and
retreat the surface before applying paint coatings or
sealants.
5-10. TEMPORARY PRESERVATION
. Under adverse
conditions or when the restriction of operations will not
permit the application of a chemical conversion coating,
apply a temporary corrosion preventive compound (CPC)
in accordance with Chapter 8.