TM-3-1040-279-12-P

GENERATOR SET, SMOKE, MECHANICAL: PULSE JET, M157 W/120 GAL FOG OIL TANK AND W/80 GAL FOG OIL TANK

TECHNICAL MANUAL; OPERATOR’S AND ORGANIZATIONAL MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST AND DEPOT MAINTENANCE REPAIR PARTS

MAY 1987

  TM-3-1040-279-12-P - Page 51 of 389

TM 3-1040-279-12&P
TROUBLESHOOTING (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. ENGINE WILL NOT START. (CONT)
Step 2.
Check for start air blast.
Set FUEL switch to OFF.
CAUTION
Do not hold ENGINE switch in START position for more than 30
seconds.
Hold ENGINE switch in the START position.
Listen for start air blast at nozzle assembly on engine head.
If start air blast is not present, set all switches and circuit breaker CB1 to OFF and notify
organizational maintenance.
If start air blast is present, set all switches and circuit breaker CB1 to OFF and go to next
step.
Change 4
3-4.1/(3-4.2 Blank)