TM 5-2330-378-14&P
4-34.
WIRING HARNESS REPLACEMENT (M870) (continued).
46.
Strip insulation from end of black circuit wire (65) at voltage reduction box (2) to depth of connector (64).
47.
Install connector (64) on black circuit wire (65) and crimp.
48.
Put connector (64) in place onjunction block (6), and install blackterminal
wire screw (4) on connector(64)
and
junction block (6).
49.
Install box cover (3) on voltage reduction box (2) and secure with six screws (1).
2
10 0
0
65
64
4
Qll%@
FOLLOW-ONTASKS:
- None