TM-5-2330-378-14-P

SEMITRAILER, LOWBED: 40 TON CONSTRUCTION EQUIPMENT TRANSPORTER M870 AND M870A1

TECHNICAL MANUAL; OPERATOR'S, UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

JUNE 1999

  TM-5-2330-378-14-P - Page 179 of 524

TM 5-2330-378-14&P
4-40. THREE-POINTTERMINALSTRIPREPLACEMENT(M870A1).
ThisTaskCovers:
a.
Removal
b.
Installation
Initial Setup:
Tools/Test Equipment:
Equipment Conditions:
- Tool kit, general mechanic's: automotive
Semitrailer unloaded (para 2-10).
(item 7, Appendix B)
Materials/Parts:
Personnel Required:
Two
- Self-locking nut (2), (item 27, Appendix 1)
a.
REMOVAL
WARNING
Disconnect all outside power before performing any maintenance on the electrical
system.
Failure to do so could result in serious injury or death.
I .
Remove two bolts (1) securing voltage reduction box cover (2) to semitrailer.
Turnover box cover (2).
2.
Tag three electrical wires (3) connected to three-point
7
6
terminal strip (4).
7
5
3.
Removethree
screws (5) holding three resistors (6) and
3
6
clips (7) to terminal strip (4). Carefully rotate resistors
7
(6) and clips (7) away from terminal strip (4).
4.
Remove three screws (8) and wires (3) from terminal
10
strip (4).
5.
Removetwo
mountingscrews
(9)and self-locking nuts
10
6
(10) from terminal strip (4), and remove terminal st6p (4)
8
4
from box cover (2). Discard self-locking nuts.
1'@
2
9
9
4-91


Back to Top