TM-5-2350-262-20-3

ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL; VOLUME 3 OF 3; HYDRAULIC TROUBLESHOOTING TEST PROCEDURES

  TM-5-2350-262-20-3 - Page 131 of 319

3-96
TM 5-2350-262-20-3
To block 25
YES
from block 8
To block 13
NO
YES
YES
NO
11
Perform suspension pressure test.
Is hydraulic pressure at least 3,900 psi (26,891 kPa)?
FRONT CORNER (LEFT OR RIGHT) RAISES IN SPRUNG, BUT NOT UNSPRUNG MODE
(CONTINUED)
7
YES
9
Stop engine; relieve hydraulic pressure.
Remove all test equipment and connect hoses.
10
Perform main pump flow test.
Does ejector fully extend in less than 32 seconds and
apron raise fully in less than 15 seconds?
12
Replace direction control valve bank.


Back to Top