  TM-5-2350-262-20-3 - Page 148 of 319

3-113
TM 5-2350-262-20-3
NO. 1 RIGHT ACTUATOR
DEPICTED
NO. 1 ACTUATOR
OIL FLOW AND HYDRAULIC PRESSURE TEST
NOTE
Have suitable container ready to catch oil.
Stop engine; relieve hydraulic pressure.
Disconnect NO 1 SPNSN UNIT-9 hose (1) at
elbow (2) on port 9 of No. 1 actuator (3).
Cap elbow (2).
Connect tee (4), globe valve (5), and pressure measuring device (6) to end of NO 1
SPNSN UNIT-9 hose (1).
Connect a drain hose (7) to open end of globe valve (5).
Place end of hose (7) in container.
Start engine.
Open globe valve (5).
Observe for flow
of oil.