TM-5-2350-262-20-3

ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL; VOLUME 3 OF 3; HYDRAULIC TROUBLESHOOTING TEST PROCEDURES

  TM-5-2350-262-20-3 - Page 149 of 319

3-114
TM 5-2350-262-20-3
NO
from block 5
YES
from block 5
To block 10
To block 11
YES
NO
YES
NO
8
FRONT CORNER (LEFT OR RIGHT) RAISES IN UNSPRUNG, BUT NOT SPRUNG MODE
(CONTINUED)
Perform front actuator pressure test.
Is pressure greater than 2,500 psi (17,238
kPa)?
9
6
Perform raise front corner test.
Does corner raise?
7
Replace No. 1 actuator.
Replace No. 2 actuator.
8