3-106
TM 5-2350-262-20-3
FRONT CORNER (LEFT OR RIGHT) RAISES IN SPRUNG, BUT NOT UNSPRUNG MODE
(CONTINUED)
7
To block 29
NO
from block 8
YES
NO
27
Perform main relief valve adjustment.
Can hydraulic pressure be adjusted to 3,950-4,050 psi
(27,235-27,925 kPa)?
28
Verify problem is solved.