TM 5-2350-262-20-3
3-174
To block 7
2
Check for blockage in REAR SPNSN UNIT-9 hose.
Is there blockage?
Perform actuator hose 9 flow test.
Is there steady flow of hydraulic oil to actuator?
1
YES
NO
YES
NO
YES
NO
11
LEFT REAR CORNER DOES NOT RAISE IN SPRUNG OR UNSPRUNG MODE (CONTINUED)
Perform left manifold blockage test.
Is port 9 pressure less than 2,500 psi (17,238 kPa)?
4
Clear or replace REAR SPNSN UNIT-9 hose.
3
Remove all test equipment and connect hose.
5
Clear or replace manifold.
Remove all test equipment and
connect hose.
6
Verify problem with operator.
Remove all test equipment and
connect hose.