TM-5-2350-262-20-3

ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL; VOLUME 3 OF 3; HYDRAULIC TROUBLESHOOTING TEST PROCEDURES

  TM-5-2350-262-20-3 - Page 203 of 319

TM 5-2350-262-20-3
3-168
NO
from block 57
To block 61
59
Perform a pressure test on all No. 1 or No. 4
actuator accumulators.
Is pressure 800-900 psi (5,516-6,206 kPa)?
YES
NO
60
Remove all test equipment and connect hoses.
Verify problem with operator.
10
HYDRAULIC OIL OVERHEATS (CONTINUED)


Back to Top