3-8
TM 5-2350-262-20-3
E
Connect tube assembly (7) to reducer (6).
F
Install two adapters (8) on globe valve (9), and connect
this assembly to tube (7), with arrow of globe valve (9)
pointed toward port 7 (3).
CAUTION
Make sure globe valve is closed when dump
valve is not in use or when engine is running.
Damage to equipment may result.
G
Connect hose assembly (10) to adapter (8) at
end of globe valve (9).
ACCUMULATOR DUMP VALVE INSTALLATION
Some procedures in the troubleshooting charts require starting and stopping the engine several times. To
rapidly and safely relieve pressure from the main hydraulic accumulator, a dump valve may be installed in the
system. If installing a dump valve, use the procedure described below.
A
Stop vehicle engine and relieve hydraulic
pressure
B
Remove plug (1) and packing (2) from port
7 (3) of valve 13R (4).
Discard packing (2).
C
Install new packing (2) and nipple (5) in port
7 (3).
D
Install reducer (6) to nipple (5).