TM-5-2350-262-20-3

ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL; VOLUME 3 OF 3; HYDRAULIC TROUBLESHOOTING TEST PROCEDURES

  TM-5-2350-262-20-3 - Page 34 of 319

INSTALLATION OF ADJUSTABLE FITTINGS
A
Apply light weight oil (OE/HDO-10) to O-ring (preformed packing).
CAUTION
Packing must be positioned fully into groove and not on threads. Failure to comply may
result in damage to equipment.
B
Gently push backup washer and O-ring all the way into groove.
C
Turn locknut down until locknut contacts backup washer.
D
Install fitting on boss until backup washer contacts face of boss.
E
Position fitting to desired position by backing out fitting up to one full turn. Hold fitting in desired position,
and tighten locknut.
F
Connect tube to fitting after fitting is properly positioned and tightened.
2-11 (2-12 blank)