TM-5-2350-378-23-P

ARMORED COMBAT EARTHMOVER (ACE), M9; HYDRAULIC DIAGNOSTIC CENTER

TECHNICAL MANUAL; FIELD MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

JUNE 2012

  TM-5-2350-378-23-P - Page 337 of 644

APPARENT HYDRAULIC DIAGNOSTIC CENTER (HDC) SYSTEM PROBLEM - Continued
PLUG
T01925HDC
Figure 25.
Upper Cable Assembly W2J1 and Lower Cable Assembly W3J1 Electrical Connections.
CONDITION/INDICATION
Does an open circuit or short circuit exist in applicable cable assembly W2 or W3 wiring circuit (CIRCUIT FAULT
solenoid valve 28 VDC energizing circuit) being checked? (Refer to FP-23 through FP-26) for wiring schematic
diagrams of electrical cable assemblies (W2 and W3).
DECISION
YES - Replace embedded cable assembly (W2 or W3 as applicable) associated with designated "CIRCUIT
FAULT" solenoid valve 28 VDC energizing circuit wiring.
NO - Go to Step (35).
TM 5-2350-378-23&P
0021
0021-25


Back to Top