APPARENT HYDRAULIC DIAGNOSTIC CENTER (HDC) SYSTEM PROBLEM - Continued
PLUG
T01927HDC
Figure 27.
Umbilical Cable Assembly W4P2 and W4P3 Electrical Connections.
SOCKET
T01928HDC
Figure 28.
Umbilical Cable Assembly W4P5 and W4P6 Electrical Connections.
CONDITION/INDICATION
Does an open circuit or short circuit exist in umbilical cable assembly W4 wiring circuit (CIRCUIT FAULT solenoid
valve 28 VDC energizing circuit) being checked?
DECISION
YES - Replace umbilical cable assembly W4. Resume HDC system functional check-out (WP
0025) .
NO - Go to Step (36).