0012 00--30
EJECTOR DOES NOT EXTEND OR RETRACT -- Continued
0012 00
YES
NO
NO
from block 17
19
Verify problem is solved.
20
Verify problem is solved.
Replace directional control valve bank
(TM 5--2350--262--20--2).
18
Can pressure be adjusted?
Perform ejector control valve adjustment
using the HDC.