TM 5--2350--378--24&P
0012 00--33
EJECTOR DOES NOT EXTEND OR RETRACT -- Continued
0012 00
Figure 23. HDC Control Box
Figure 24. DCV Bank
Figure 25. Ejector Control Valve
EJECTOR CONTROL VALVE ADJUSTMENT -- CONTINUED
Disable ejector by manually closing the ejector inhibit ball valve V23 (Figure 24, item 1)
on the DCV bank. Using LINE UP or LINE DOWN button (Figure 23, item 3), select V1
on the HDC display (Figure 23, item 2). Close V1 on the HDC display (Figure 23, item 2)
by selecting the CHANGE POSITION button (Figure 23, item 4) on the HDC control box.
Start engine. With the engine at idle speed and EJECTOR CONTROL lever in
FORWARD position, loosen jam nut (Figure 25, item 1) on ejector control valve and turn
adjusting screw (Figure 25, item 2) clockwise to increase pressure; counterclockwise to
decrease pressure. Transducer T--2 hydraulic pressure on the HDC display (Figure 23,
item 1) should indicate 1,950--2,050 psi (13,445--15,135 kPa).
Stop engine; relieve hydraulic pressure
Manually open the ejector inhibit ball valve V23 (Figure 24, item 1) on the DCV bank.
Using LINE UP or LINE DOWN button (Figure 23, item 3), select V1 on the HDC display
(Figure 23, item 2). Close V1 on the HDC display (Figure 23, item 2) by selecting the
CHANGE POSITION button (Figure 23, item 4) on the HDC control box.