TM-5-2350-378-24-P

HYDRAULIC DIAGNOSTIC CENTER (HDC) SUPPORTING ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

  TM-5-2350-378-24-P - Page 297 of 790

TM 5--2350--378--24&P
0015 00--4
FRONT CORNER (LEFT OR RIGHT) DOES NOT RAISE IN SPRUNG OR UNSPRUNG
MODE -- Continued
0015 00
To block 4
YES
3
NO
Notify Direct Support maintenance
to replace No. 1 actuator.
NO
YES
2
Perform front actuator port 3 pressure test using the
HDC.
Is transducer T--5 (right) and T--6 (left) hydraulic
pressure greater than 2,500 psi (17,238 kPa)?
1
Perform front actuator port 9 pressure test using the
HDC.
Is transducer T--8 (right) and T--9 (left) hydraulic pres-
sure greater than 2,500 psi (17,238 kPa)?