TM-5-2350-378-24-P

HYDRAULIC DIAGNOSTIC CENTER (HDC) SUPPORTING ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

  TM-5-2350-378-24-P - Page 303 of 790

TM 5--2350--378--24&P
0015 00--10
FRONT CORNER (LEFT OR RIGHT) DOES NOT RAISE IN SPRUNG OR UNSPRUNG
MODE -- Continued
0015 00
YES
11
Clear blockage or replace line.
Verify problem is solved.
13
Verify problem with operator.
NO
from block 9
YES
from block 9
NO
12
Notify Direct Support mainte-
nance to replace No. 2 actuator.
Check for blockage in line between No. 1 and No. 2
actuators.
Is there blockage?
10
END OF WORK PACKAGE


Back to Top