TM 5--2350--378--24&P
0016 00--4
HYDRAULIC OIL OVERHEATS -- Continued
0016 00
YES
NO
1
Perform HDC manual valve status check.
Ensure that manually--operated HDC
valves V21, V22 and V23 are open.
Are all manual valves open?
Open valves.
NO
YES
2
Perform HDC solenoid valve V19
test.
Is transducer T--1 hydraulic pressure
greater than 1,000 psi (6894.757 kPa)?
Replace solenoid valve V19
on HDC primary manifold
(WP 0035 00).
To block 3