TM-5-2350-378-24-P

HYDRAULIC DIAGNOSTIC CENTER (HDC) SUPPORTING ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

  TM-5-2350-378-24-P - Page 287 of 790

TM 5--2350--378--24&P
0014 00--16
FRONT CORNER (LEFT OR RIGHT) RAISES IN UNSPRUNG, BUT NOT SPRUNG MODE --
Continued
0014 00
19
Clear blockage.
Verify problem is solved.
To block 21
YES
NO
YES
NO
from block 3
and 4
NO
18
Check for blockage between inlet port 9 of
forward manifold and port 9 of No. 1 actuator,
and between left main manifold and No. 1
actuator.
Is there blockage?
20
Verify problem with operator.
17
Perform forward manifold pressure test using the
HDC.
Is transducer T--7 (left) and T--8 (right) hydraulic
pressure greater than 2,500 psi (17,238 kPa)?


Back to Top