TM 5--2350--378--24&P
0014 00--9
FRONT CORNER (LEFT OR RIGHT) RAISES IN UNSPRUNG, BUT NOT SPRUNG MODE --
Continued
0014 00
Figure 5. No. 1 Right Actuator
RAISE FRONT CORNER TEST
NOTE
Have suitable container ready to catch oil.
Disconnect SPNSN UNIT--2 hose (Figure 5, item 1) from port 2 on No. 1 actuator
(Figure 5, item 2). Cap and plug port 2 and SPNSN UNIT--2 hose (Figure 5, item 1).
Start engine. Move SPRUNG/UNSPRUNG lever to SPRUNG mode.
Stop engine; relieve hydraulic pressure and connect hoses.