TM 5--2350--378--24&P
0014 00--13
FRONT CORNER (LEFT OR RIGHT) RAISES IN UNSPRUNG, BUT NOT SPRUNG MODE --
Continued
0014 00
Figure 7. SPRUNG/UNSPRUNG Control Valve Linkage
SPRUNG/UNSPRUNG CONTROL VALVE LINKAGE CHECK
Hold measuring device (Figure 7, item 1) on face of SPRUNG/UNSPRUNG control valve
(Figure 7, item 2). Have assistant move SPRUNG/UNSPRUNG lever between SPRUNG
and UNSPRUNG mode. Measure distance plunger (Figure 7, item 3) travels as lever is moved.
Distance of travel should be 9/32 in. (7 mm).