TM 5--2350--378--24&P
0014 00--5
FRONT CORNER (LEFT OR RIGHT) RAISES IN UNSPRUNG, BUT NOT SPRUNG MODE --
Continued
0014 00
Figure 3. HDC Control Box
SOLENOID VALVE V19 TEST
Start engine.
Reset all HDC solenoid valves by selecting the RESET VALVES button (Figure 3,
item 5) on the HDC control box.
Using LINE UP or LINE DOWN button (Figure 3, item 3) on the HDC control box.
Select V5 on the HDC display (Figure 3, item 2), and using the CHANGE POSITION
button (Figure 3, item 4), close V5 on the HDC display (Figure 3, item 2).
Move SPRUNG/UNSPRUNG lever to UNSPRUNG. Read transducer T--1 hydraulic
pressure on the HDC display (Figure 3, item 1).
Using LINE UP or LINE DOWN button (Figure 3, item 3) on the HDC control box, select
V5 on the HDC display (Figure 3, item 2). Using the CHANGE POSITION button
(Figure 3, item 4), open V5 on the HDC display (Figure 3, item 3).
Stop engine; relieve hydraulic pressure.