TM 5--2350--378--24&P
0013 00--42
FRONT CORNER (LEFT OR RIGHT) RAISES IN SPRUNG, BUT NOT UNSPRUNG MODE --
Continued
0013 00
YES
NO
36
37
NO
from block 31
or 33
Notify Direct Support maintenance to
replace main hydraulic pump.
Replace directional control valve (DCV)
bank (TM 5--2350--262--20--2).
35
Does transducer T--3 hydraulic pressure
indicate that main pump develops
3,950--4,050 psi (27,235--27,925 kPa)?
Perform main hydraulic pump test using
the HDC.