TM 5--2350--378--24&P
0013 00--35
FRONT CORNER (LEFT OR RIGHT) RAISES IN SPRUNG, BUT NOT UNSPRUNG MODE --
Continued
0013 00
Figure 19. Main Pump Suction Hose Blockage Test
MAIN PUMP SUCTION HOSE BLOCKAGE CHECK
WARNING
Do not work under vehicle unless hull has been properly blocked or
allowed to settle on bump stops. Failure to comply may result in
severe injury or death to personnel.
NOTE
Have suitable container ready to catch oil.
Stop engine; relieve hydraulic pressure.
Loosen, but do not disconnect, PUMP SUCT TUB--7 (Figure 19, item 1) from elbow
(Figure 19, item 3) on main hydraulic pump (Figure 19, item 2). Hydraulic oil should flow
freely from the loosened fitting. Reconnect line.