TM 5--2350--378--24&P
0014 00--4
FRONT CORNER (LEFT OR RIGHT) RAISES IN UNSPRUNG, BUT NOT SPRUNG MODE --
Continued
0014 00
To block 3
YES
NO
1
Perform V19 test.
Is transducer T--1 hydraulic pressure
greater than 500 psi (3447.79 kPa)?
2
Replace solenoid V19 on primary
manifold (WP 0035 00).