TM 5--2350--378--24&P
0014 00--10
FRONT CORNER (LEFT OR RIGHT) RAISES IN UNSPRUNG, BUT NOT SPRUNG MODE --
Continued
0014 00
To block 12
To block 13
YES
NO
YES
from block 7
Is transducer T--10 (front left) and T--11
(front right) pressure greater than 2,500 psi
(17,238 kPa)?
11
Perform front actuator pressure test using
the HDC.