TM-5-2350-378-24-P

HYDRAULIC DIAGNOSTIC CENTER (HDC) SUPPORTING ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

  TM-5-2350-378-24-P - Page 319 of 790

TM 5--2350--378--24&P
0016 00--16
HYDRAULIC OIL OVERHEATS -- Continued
0016 00
YES
from block 6
NO
from block 13
15
YES
from block 13
YES
NO
14
Perform pressure test on suspension relief valve
using the HDC.
Is transducer T--13 hydraulic pressure
3,700--3,800 psi (25,512--26,201 kPa)?
Replace compensating pump
(TM 5--2350--262--20--2).
To block 19
To block 16


Back to Top