TM 5--2350--378--24&P
0016 00--16
HYDRAULIC OIL OVERHEATS -- Continued
0016 00
YES
from block 6
NO
from block 13
15
YES
from block 13
YES
NO
14
Perform pressure test on suspension relief valve
using the HDC.
Is transducer T--13 hydraulic pressure
3,700--3,800 psi (25,512--26,201 kPa)?
Replace compensating pump
(TM 5--2350--262--20--2).
To block 19
To block 16