TM 5--2350--378--24&P
HYDRAULIC OIL OVERHEATS -- Continued
0016 00
Figure 12. HDC Control Box
Figure 13. DCV Bank
SUSPENSION RELIEF VALVE ADJUSTMENT -- CONTINUED
Manually close the ejector inhibit ball valve V23 (Figure 13, item 1) on the DCV bank.
Using LINE UP or LINE DOWN button (Figure 12, item 2) on the HDC control box;
select V5 on the HDC display (Figure 12, item 1). Using the CHANGE POSITION
button (Figure 12, item 3), close V5 on the HDC display (Figure 12, item 1). Repeat
steps for V12, V13 and V19, closing V12 and V13, and opening V19.
Start engine.
Continued on page 0016 00--25.
0016 00--23/24 blank