TM 5--2350--378--24&P
0016 00--26
HYDRAULIC OIL OVERHEATS -- Continued
0016 00
20
Stop engine; relieve hydraulic pressure.
19
Perform main hydraulic pump pressure test using
the HDC.
YES
from block 16
To block 21
YES
NO
18
Stop engine; relieve hydraulic pressure.
Verify problem is solved.
Does main hydraulic pump develop 3,950--4,050 psi
(27,235--27,925 kPa)?
Replace main hydraulic pump
(TM 5--2350--262--20--2).
YES
from blocks 7,
8, and 15