TM-5-2350-378-24-P

HYDRAULIC DIAGNOSTIC CENTER (HDC) SUPPORTING ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

  TM-5-2350-378-24-P - Page 409 of 790

TM 5--2350--378--24&P
0017 00--8
LEFT REAR CORNER DOES NOT RAISE IN SPRUNG OR UNSPRUNG MODE -- Continued
0017 00
7
Is #3 left actuator leaking internally?
YES
from block 1
YES
NO
Perform No. 3 left actuator internal leakage test
using HDC (pressure transducer T--7).
Transducer T--7
pressure less than
2500 psi (17, 238 kPa).
Transducer T--7 pressure
equal or greater than
2500 psi (17, 238 kPa).
To block 8
To block 10