TM 5--2350--378--24&P
0004 00--23
INTRODUCTION TO TROUBLESHOOTING AND REPAIR OF THE M9 ACE HYDRAULIC
SYSTEM -- Continued
0004 00
ACCUMULATOR DUMP VALVE INSTALLATION -- CONTINUED
8.
Disconnect ACCUMULATOR--9 hose (Figure 19, item 5) from elbow (Figure 19, item 3) at bottom of main
hydraulic accumulator (Figure 19, item 2).
9.
Install tee (Figure 19, item 4) on elbow (Figure 19, item 3), and connect hose (Figure 19, item 5) and
hose assembly (Figure 19, item 1) to tee (Figure 19, item 4).
Figure 19. Accumualtor Dump Valve Installation
Figure 20. Accumulator Dump Valve Installation