TM-5-3805-254-20-1

TRUCK, DUMP, 20 TON, 6X4, ON-OFF HIGHWAY 71,000 GVW, IHC MODEL F-5070 (CCE)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL VOLUME 1 OF 2

JANUARY 1988

  TM-5-3805-254-20-1 - Page 713 of 790

TM 5-3805-254-20-1
RADIATOR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
DRAINING
2.
Coolant
Check coolant protection (TB 750-651).
3.
Cap (2)
Put on and turn clockwise.
NOTE
If drained coolant is not contaminated, save it for later use.
If coolant is contaminated, get rid of it
and use new coolant.
4.
Radiator (1)
Cap (2)
Turn counterclockwise and take off.
5.
Radiator outlet
Draincock (4)
a.
Place 6-gallon container underneath.
pipe (3)
b.
Using 8-inch slip-joint pliers, turn
counterclockwise to open.
c.
Allow coolant to drain.
d.
When 6-gallon container is filled, turn
clockwise to close.
e.
Get rid of coolant.
See note above.
f.
Repeat steps a thru e until all coolant is
drained.
2-629