TM-5-3805-254-20-1

TRUCK, DUMP, 20 TON, 6X4, ON-OFF HIGHWAY 71,000 GVW, IHC MODEL F-5070 (CCE)

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE MANUAL VOLUME 1 OF 2

JANUARY 1988

  TM-5-3805-254-20-1 - Page 722 of 790

TM 5-3805-254-20-1
WATER FILTER - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
1.
Radiator (1)
Shutoff valve (2)
Using 8-inch slip-joint pliers, turn clock-
wise to close.
2.
Water manifold (3)
Shutoff valve (4)
Using 8-inch slip-joint pliers, turn clock-
wise to close.
3.
Filter base (5)
Water filter (6)
a.
Using filter wrench, unscrew and take
off.
b.
Get rid of.
INSTALLATION
4.
New water
Hand tighten one-half to three-quarters turn
filter (6)
until gasket touches filter base.
5.
Water manifold (3)
Shutoff valve (4)
Turn counterclockwise to open using 8-inch
slip-joint pliers.
6.
Radiator (1)
Shutoff valve (2)
Turn counterclockwise to open using 8-inch
slip-joint pliers.
NOTE
FOLLOW-ON MAINTENANCE:.
1.
Refill cooling system (page 2-628).
2.
Close right side hood panel (page 2-424).
TASK ENDS HERE
2-638


Back to Top