TM-5-3805-264-13-P

TRUCK, DUMP, HEAVY, BODY M917A1 AND M917A2

TECHNICAL MANUAL; OPERATOR AND FIELD MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

JUNE 2014

  TM-5-3805-264-13-P - Page 163 of 660

Table 1.
Preventive Maintenance Checks and Services (PMCS) for M917A1, M917A1 with Material Control
System (MCS), M917A2, and M917A2 with MCS - Continued.
ITEM
NO.
INTERVAL
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
WARNING
To prevent burns, use caution when
removing fill cap of hydraulic reservoir when
hydraulic fluid is hot. Avoid contact with hot
hydraulic oil. Failure to comply may result in
personnel injury.
2. Remove fill cap from reservoir. Clean fill cap vent in
accordance with General Maintenance Instructions
(WP 0072). Install fill cap.
WARNING
DO NOT disconnect hydraulic lines while
engine is running. Engine must be shut
down and dump body fully lowered or
supported on body props before lines are
disconnected. Failure to comply may result
in personnel injury.
3. Inspect all hydraulic lines, fittings, and components
for signs of leaks. Tighten any connections that are
loose. Ensure that hydraulic lines are supported.
Replace any damaged component.
8
Semiannual Stabilizer
WARNING
NEVER work under a raised dump body
unless it is secured in the raised position
with body props and dump body is EMPTY.
Failure to comply may result in personnel
injury or death.
Inspect stabilizer for loose mounting or damage. If
damaged, notify your supervisor.
TM 5-3805-264-13&P
0019
0019-5


Back to Top