TM-5-3805-264-13-P

TRUCK, DUMP, HEAVY, BODY M917A1 AND M917A2

TECHNICAL MANUAL; OPERATOR AND FIELD MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

JUNE 2014

  TM-5-3805-264-13-P - Page 165 of 660

Table 1.
Preventive Maintenance Checks and Services (PMCS) for M917A1, M917A1 with Material Control
System (MCS), M917A2, and M917A2 with MCS - Continued.
ITEM
NO.
INTERVAL
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
12
Annual
Decals and
Stencils
Check all decals and stencils to ensure legibility.
13
10,000
Miles or
Annual
Hydraulic
Reservoir
WARNING
To prevent burns, use caution when
removing fill cap of hydraulic reservoir when
hydraulic fluid is hot. Avoid contact with hot
hydraulic oil. Use extreme care when
draining hydraulic oil. Failure to comply may
result in personnel injury or death.
1. With dump body down and engine off, remove
magnetic drain plug from underside of reservoir
(Figure 2, Item 4). Drain hydraulic oil into a suitable
container, and dispose of in accordance with local
procedures.
2. Remove fill cap (Figure 2, Item 2). Remove strainer
from reservoir (Figure 2, Item 4) (WP 0067). Clean
strainer and reinstall.
3. Replace hydraulic oil filter element (WP 0063).
4. Clean drain plug and reinstall.
NOTE
Hydraulic reservoir capacity is 12.75 gal.
(48.2 l). DO NOT overfill.
5. Fill reservoir (Figure 2, Item 4) with lubricating oil
until level of fluid in sight tube (Figure 2, Item 1) is at
FULL mark as indicated on oil level decal
(Figure 2, Item 3). Install fill cap (Figure 2, Item 2).
TM 5-3805-264-13&P
0019
0019-7


Back to Top