TM 5-3895-372-20
Table 5-1.
Water System Troubleshooting Procedures (Continued).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
MIX WATER DOES NOT FLOW AT A STEADY RATE (Continued):
NOTE
If a pressure gage is not available, adjust pressure so that water can be sprayed
about 35 ft with washout hose.
Step 8. Check for air trapped in water lines.
Bleed air by squirting water from the washout hose until it flows in a steady stream.
Step 9. If temperature is below 320F (0°C) check for frozen water lines.
a.
Open draincocks.
b.
Apply heat to melt ice.
c.
When system is free of ice, close draincocks.
2.
WATER LINE VALVES LEAK:
a.
Engage PTO. Pump speed should be 1620-1720 rpm.
b.
Check each valve for leakage.
Replace leaking valves (para 5-12 & 5-13).
3.
QUICK-OPENING VALVE STICKS;
Step 1. Check for sticking or binding as valve is opened and closed.
a.
Lubricate valve stem with engine oil. Repack rubber boot,
if necessary.
5-4